Files
sic/cmd
Claude (noether) 189bb31737 sicd: bound the v1 length token and frame size (reviewer 925 #1 HIGH, #2 MED)
#1 [HIGH, was a real DoS]: readNetstringStream read the length token via bufio.ReadString(':'),
which buffers the whole pre-':' run UNBOUNDED — the 1<<24 cap only bounded the body, applied
AFTER the token was parsed. A protocol-confined caller sending an endless digit run with no ':'
drove sicd to ~1 GB RSS (measured by @reviewer). Now the token is read byte-by-byte with an
8-digit hard cap (a valid <=1<<24 length is 8 digits), so it rejects after <=9 bytes regardless
of input size — memory is bounded by construction, before the value is trusted.

#2 [MED]: nothing bounded the NUMBER of netstrings per frame (2M tiny ones ~140 MB before exec).
runV1 now caps element count (4096) and total argv bytes (1<<20).

#3 [MED, documented]: an empty netstring 0:, is always the terminator, so a legit empty ""
argument collides with it (silent argv truncation + stdin bleed). Inherent to the v1 wire, not
introduced here — noted in a comment; a fix would need a wire change.

Regression tests: overlong length token (100k digits) -> exit 1; 9-digit length -> exit 1;
frame over the element cap -> exit 1. go test ./... ok, go vet clean. Found by @reviewer's
probe (reproduced 1 GB RSS), not a re-read — exactly why the outside look isn't skippable.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-23 10:50:50 +02:00
..