Claude (noether) 3982706ebb sicd: reject malformed netstrings (security), and retire an unsatisfiable read-error test
FINDING 1 (security) — the Go daemon accepted netstrings the Python reference REJECTS and
then EXECUTED them, so a malformed frame that fails closed on a Python hop ran on a Go hop.
parse_netstring now matches gateway/sicd exactly: reject non-digit lengths (incl. a leading
'+'/'-'), reject lengths > 1<<24, reject trailing bytes after the closing comma. The three
cases now exit 1 with a diagnostic instead of exec'ing. Both suites pin them (the Python
suite didn't either, which is how this slipped through green tests).

FINDING 2 (read-error path) — TestStdinReadErrorDiagnosedNotSwallowed is SKIPPED, with the
rationale in the skip string, because its premise is false in Go. It injected a fault by
closing a pty master mid-pump, assuming the slave read returns EIO — true for CPython's
os.read(), but Go's runtime poller delivers a clean EOF instead (probed directly: slave.Read
-> io.EOF, io.Copy -> nil; a socketpair peer close is EOF too — SO_LINGER/RST is TCP-only).
No fd mechanism available to the test produces a distinguishable READ error on sicd's stdin.
That is not a gap in main.go: the trailing stdin is UNFRAMED by design, so a truncated source
and a clean end are BOTH EOF and cannot be told apart — the pump treats EOF as a legitimate
end and already reaps-then-exits-nonzero on a genuine non-EPIPE error (kept in main.go), which
just doesn't arise via pty/socket close in Go.

Two local models burned 20+ grind attempts trying to satisfy this test before the premise was
probed — a textbook "a failure that looks like incapability is instrumentation." Proper
coverage for the reap-on-real-error branch = refactor the pump into a unit-testable func fed by
an io.Reader that returns a non-EOF error; left as a follow-up.