9a023e9264
3 in-session reps of chromium-fourier 149 / brave_drops_test.html /
Plasma Wayland 6.6.4 (kwin-fourier 6.6.4-3 + qt6-base-fourier
6.11.0-3 carry-overs intact). Tight cluster IQR=0:
drops_total=0, drops_post_warmup=0, frames_total=1685, kwin %CPU
median=0.00, mean=0.04. Perf samples on kwin (~30 over 70s) show
zero composite/dmabuf/GL symbols — only event-loop bookkeeping.
Most likely mechanism: KWin direct-scanout fast-path engaged for
the single-visible-client video case. The campaign's load-bearing
hypothesis ("X11 + non-compositing WM avoids per-frame GL composite
of NV12") is structurally weakened — KWin already avoids that work
under Wayland for this workload. Phase 1 needs to add a
multi-window A1' variant and drm_info-during-playback to confirm
direct-scanout, then revisit matrix cell design.
revert.log entry 6: SDDM autologin + state.conf swap that landed
the Plasma Wayland session for the A1 reps. Backup of original
state.conf preserved at /var/lib/sddm/state.conf.x11-research-bak;
single-command revert documented.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
7 lines
279 B
Plaintext
7 lines
279 B
Plaintext
samples=71
|
|
drops_total=0
|
|
frames_total=1686
|
|
drops_post_warmup=0
|
|
warmup_first_t=10.01
|
|
end_line=[38005:38005:0503/143126.725506:INFO:CONSOLE:44] "DROPS_TRAJECTORY: ===END=== total=1686 dropped=0 elapsed=70.10", source: file:///home/mfritsche/fourier-test/brave_drops_test.html (44)
|